Electrical Power & Distribution Transformers

Rating range: Typically 25–2,500 kVA

Oil-immersed three-phase transformers, typically 25–2,500 kVA.

Voltage ratio
11 kV / 433 V (typical)
Cooling
ONAN (oil natural, air natural)
Vector group
Dyn11 (typical)
Typical values for the product class. Ratings and options are agreed for each requirement.

Have a different requirement? Share your application and preferred configuration.

Made for the application.

Invitrona manufactures three-phase, oil-immersed transformers with natural oil and air cooling for distribution and industrial power duties, typically from 25 to 2,500 kVA. The usual arrangement steps 11 kV down to 433 V with a Dyn11 vector group and off-circuit tapping; other voltage ratios and fittings are agreed per project. The principal electrical, loss and installation parameters are fixed together so that a project team can move from a requirement to a focused specification.

Typical application contexts

  • Industrial plant power distribution
  • Commercial and institutional campuses
  • Residential developments and townships
  • Pumping stations and utilities
  • Dedicated supplies for large machinery

Agreed electrical schedule

Rating, voltage ratio, vector group, impedance and tapping are fixed together in one schedule for the project.

Off-circuit tapping

Taps allow the secondary voltage to be adjusted to the actual supply level after installation, with the transformer isolated.

Oil-immersed construction

Natural oil and air cooling suits outdoor installation without auxiliary fans or pumps.

Protection fittings

Oil level, temperature and pressure fittings give the site the indications its protection scheme needs.

Project terminations

Bushings or cable boxes are arranged to suit the incoming and outgoing connections.

Technical specifications

Typical values for the product class. The ratings, options and operating conditions for your equipment are confirmed during engineering review and stated in the quotation.

Electrical Power & Distribution Transformers — typical specifications
ParameterValueCondition
Rating rangeTypically 25–2,500 kVAContinuous duty, three phase
High-voltage winding11 kV class (typical)22 kV and 33 kV classes by assessment
Low-voltage winding433 V, three phase with neutralOther secondary voltages by assessment
Frequency50 Hz
Vector groupDyn11 (typical)Other groups to suit parallel operation or the system
TappingOff-circuit, typically ±5% in 2.5% stepsOn-load tap changer by assessment
CoolingONAN (oil natural, air natural)Mineral insulating oil
ImpedanceTypically 4.5–6.25%Depends on rating; stated in the quotation
EfficiencyTypically 98–99%At rated load and unity power factor; depends on rating and loss level
Windings and coreCopper or aluminium windings; CRGO steel coreSelected for the rating and loss requirement
FittingsConservator, oil level indicator, breather, thermometer pocket, pressure relief deviceBuchholz relay and winding temperature indicator by rating or project
Ambient and altitudeUp to 50 °C ambient; up to 1,000 m altitudeDerating for higher altitude
InstallationOutdoor plinth mounted; pole mounted for small ratingsCable boxes or bushings as agreed

Documents & next steps

PDFElectrical Power & Distribution Transformers datasheetTypical specifications · Typically 25–2,500 kVA

Drawings and documents for a specific order are agreed during engineering review.

For a useful first conversation

  • System voltage, fault level, load schedule and connection requirements
  • Installation environment, cooling, access and enclosure constraints
  • Protection, termination, indication and interface expectations
  • Applicable project, inspection and documentation requirements
Share your requirement

Common questions

A little context before you enquire.

What decides the transformer rating?

The maximum demand of the connected load, its diversity, expected growth and the ambient conditions. Motor starting and harmonic-producing loads are reviewed separately because they can need a higher rating.

Which voltage ratio and vector group should I specify?

Most low-voltage distribution in India uses 11 kV to 433 V with Dyn11. Where a transformer will run in parallel with existing units, the vector group, ratio and impedance must match them.

Do I need on-load tap changing?

Off-circuit tapping suits supplies with a steady level. An on-load tap changer is considered where the supply varies during operation and the load cannot be interrupted for tap changes.

Which standards apply to distribution transformers?

In India the standard for oil-immersed distribution transformers is IS 1180, and IS 2026 covers power transformers. The standards and tests that apply to an order are stated in the quotation.

What site information is needed?

Supply voltage and fault level, load schedule, installation location, access for delivery and lifting, and the cable or busbar connection arrangement.

Where it is used

Application pathways that commonly start with this product class.

Let’s talk about your application.

Tell us what you’re working on. We’ll start with your application, load and installation needs.